In case the battery monitor is going to be used to monitor a second battery, battery bank midpoint or battery temperature, see one of the next 3 paragraphs on how to do this and then go to the Configuration chapter. In order to be fully functional, the battery monitor needs to be configured see the Configuration chapter. the Bluetooth LED will start blinking and Bluetooth is active. Note that up until 2020, the SYSTEM MINUS connection was labelled LOAD MINUS.Ĭonnect the ferrule pin of the red cable with the fuse to the shunt by pushing the pin into to the “ Vbatt +” terminal.Ĭonnect the M10 eye terminal of the red cable with the fuse to the positive terminal of the battery. Make sure that the negative of all DC loads, inverters, battery chargers, solar chargers and other charge sources are connected “after” the shunt. Tighten the shunt bolt with a maximum torque of 21Nm. Any loads or chargers connected here will be excluded from the battery state of charge calculation.Ĭonnect the negative of the electrical system to the M10 bolt on the " SYSTEM MINUS" side of the shunt. Note that there should be no other connections on this side of the shunt or on the negative battery terminal. Incorrect auxillary battery voltage readingĬonnect the negative battery terminal to the M10 bolt on the " BATTERY MINUS" side of the shunt. State of charge does not increase fast enough or too fast when charging There is a current reading while no current flows Battery system monitor, Models TM-2030-RV and TM-2030-A Technical Manual INSTALLATION -7 USER GUIDE -23 revised June 2017 IMPORTANT: The wiring installation for this meter, especially the shunt installation must be performed by someone knowledgeable in proper wiring, electrical practices, and safety. Charge and discharge current are inverted What to do in case of an alarm during discharging What to do in case of an alarm during charging Connecting and monitoring midpoint in a 48V battery bank Connecting and monitoring midpoint in a 24V battery bank Battery bank and midpoint wiring diagrams Saving, loading and sharing settings in VictronConnect The terminal block is labelled, ensure you follow the wiring diagram and follow. Accessing settings via the VictronConnect app To connect using your own wiring harness use the supplied terminal block. Connecting to a GX device and the VRM portal Accessing historical data via the VictronConnect app Auxiliary connection for temperature monitoring Auxiliary connection midpoint battery bank monitoring Auxiliary connection for monitoring the voltage of a second battery Negative is generally common and is located at main battery.
0 Comments
Leave a Reply. |
AuthorWrite something about yourself. No need to be fancy, just an overview. ArchivesCategories |